TM 5-4320-300-14
4-13.
AIR CLEANER
ASSEMBLY
This task covers:
a.
Removal
b.
Installation/Replacement
c.
covers:
INITIAL
SETUP:
Tools
Elbows (2)
Tool kit, general mechanics automotive
Nipple
NSN
5180-00-177-7033
Washers (2)
Hose (restriction indicator)
Materials/Parts
Mounting bands (2)
Antiseize (Teflon) tape, 1/2 inch
Screws (4)
(Item 18, Appendix E)
Troubleshooting References
Rags
Malfunction 5, step 2
Clamps (2)
Special
Environmental Conditions
Restriction indicator
Adequate ventilation required during
Reducer bushing
cleaning and test.
Location/Item
Action
Remarks
REMOVAL
1.
Air cleaner
Loosen hose clamp on outlet side of cleaner.
assembly
Remove mounting band clamp screws and
nuts. Remove
air cleaner
with air inlet hood.
4-81