TM 5-4320-300-14Table 4-2. Organizational Maintenance Troubleshooting - ContinuedMALFUNCTIONTEST OR INSPECTIONCORRECTIVE ACTIONIf oil is to be reused, remove oil filler capand pour approximately 50%, or less, ofthe collected oil into the oil filler. Waitseveral minutes and check oil level.Pour enough of the remaining oil into theoil filler to bring the crankcase oil level toF on the dipstick.CAUTIONDo not overfill. Oil may be blown out throughthe crankcase breather if crankcase is overfilled.If crankcase is to be refilled with fresh oil, discard old oil. Remove and discard filter cartridge. Inspectfilter adaptor on the engine for nicks, burrs, or other damage. Before installing new filter cartridge, coatfilter gasket with oil and wipe off filter adaptor before screwing the filter cartridge on hand tight. Runengine for a few minutes and check for filter leaks. Retighten if necessary.Fill crankcase through oil filter with oil to F on dipstick.4-54