TM 5-4320-300-14
Table 4-2. Organizational Maintenance Troubleshooting - Continued
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
If oil is to be reused, remove oil filler cap
and pour approximately 50%, or less, of
the collected oil into the oil filler. Wait
several minutes and check oil level.
Pour enough of the remaining oil into the
oil filler to bring the crankcase oil level to
F on the dipstick.
CAUTION
Do not overfill. Oil may be blown out through
the crankcase breather if crankcase is overfilled.
If crankcase is to be refilled with fresh oil, discard old oil. Remove and discard filter cartridge. Inspect
filter adaptor on the engine for nicks, burrs, or other damage. Before installing new filter cartridge, coat
filter gasket with oil and wipe off filter adaptor before screwing the filter cartridge on hand tight. Run
engine for a few minutes and check for filter leaks. Retighten if necessary.
Fill crankcase through oil filter with oil to F on dipstick.
4-54