PREPARATION FOR STORAGE OR SHIPMENT
PREPARATION FOR STORAGE OR SHIPMENT - Continued

Field Maintenance Manual Tools List For Engineer Mission Module - Water Distributor Page Navigation
  1144    1145    1146    1147    1148  1149  1150    1151    1152    1153    1154  
img
. . . . . . . . . .
TM 5-3825-270-23&P
0217
STORAGE - Continued
f.
Ensure the fuel tank contains at least 4 gal (15 L) of treated fuel. The fuel should be treated with a fuel
fungus inhibitor (WP 0224, Table 1, Item 5, 6, 7, 8). The addition of 1/4 teaspoons (4 ml) of fuel fungus
inhibitor (WP 0224, Table 1, Item 5, 6, 7, 8) to 4 gal (15 L) of fuel will provide adequate protection against
fungus growth. When storing a water distributor in freezing conditions, the addition of 1/4 ounces (0.74
ml) of isopropyl alcohol to 4 gal (15 L) of fuel will help prevent fuel line freeze up.
g.
Check condition of engine air filter elements. Service (WP 0170) if necessary.
h.
Coat all exposed, unpainted surfaces with grease to prevent against deterioration.
CAUTION
Do not allow baking soda solution to enter batteries. Failure to comply may result in
damage to equipment.
i.
Clean batteries (WP 0082) and battery cables with a baking soda solution and rinse with fresh water.
Add water to battery electrolyte if necessary. Check the specific gravity of the batteries regularly. Keep
the batteries fully charged and clean according to TM 5-3825-270-23&P (WP 0221).
j.
If possible, store water distributors close together, out of direct sunlight, and away from electrical or
generating equipment.
k.
Position water distributor to allow access for inspection, maintenance, and exercising.
CAUTION
The alternator drains the batteries at all times. Batteries will discharge during storage if
not disconnected.
l.
Disconnect batteries (WP 0085).
2.
While water distributor is in storage, perform the following tasks monthly:
a.
Connect batteries (WP 0085).
b.
If engine is run every 30 days or less, use lubricating oil OE/HDO 15W40 (MIL-L-2104). If engine is not
run every 30 days or less, use lubricating oil (MIL-L-21260C, Grade 2) and change oil filter or warranty
will not be maintained.
c.
Conduct visual inspection of the water distributor. Check for fluid leaks, lubricant levels, battery
electrolyte, and coolant level. Correct any deficiencies.
d.
Fill water distributor. (TM 5-3825-270-10) with 300 gallons (1135 L) or more.
e.
Start engine and idle for 5 minutes. After 5 minutes of engine idle, circulate water (TM 5-3825-270-10)
for 5 minutes at 1500 rpm, or until the engine temperature reaches 180 F (82 C).
f.
Check grease coating on all unpainted surfaces. If grease was wiped away inadvertently, recoat these
surfaces.
g.
Fully drain water distributor. (TM 5-3825-270-10)
h.
Disconnect batteries (WP 0085). If batteries are not going to be charged for over 30 days, remove
batteries (WP 0086) from water distributor and keep fully charged according to TM 5-3825-270-23&P
(WP 0221).
3.
While water distributor is in storage, perform the following tasks quarterly:
Perform all monthly Preventive Maintenance Checks and Services (PMCS).
4.
While water distributor is in storage, perform the following tasks yearly:
a.
Perform all quarterly tasks.
0217-2