TM 5-3825-270-23&P
0201
REMOVAL - Continued
4
5
6
7
9
10
8
2
Figure 2. Suction Tube and Hose Removal.
3.
Remove eight locknuts (Figure 2, Item 5), two flange reinforcement plates (Figure 2, Item 7), suction tube
(Figure 2, Item 2), and gasket (Figure 2, Item 6) from pump (Figure 2, Item 4). Discard locknuts and gasket.
4.
Remove suction tube (Figure 3, Item 2) and clamps (Figure 3, Item 1) from suction hose (Figure 3, Item 3).
1
2
3
Figure 3. Suction Tube and Hose Removal.
END OF TASK
INSTALLATION
1.
Install suction tube (Figure 4, Item 2) on water pump (Figure 4, Item 4) with gasket (Figure 4, Item 6), two
flange reinforcement plates (Figure 4, Item 7), and eight locknuts (Figure 4, Item 5).