1
2
Figure 1. Water Pump Oil Service.
2.
Remove water pump drain plug (Figure 1, Item 1) from water pump assembly (Figure 1, Item 2) and allow oil
to drain until flow stops.
WARNING
Adhesives, solvents, and sealing compounds can burn easily, can give off harmful vapors,
and are harmful to skin and clothing. Keep away from open fire and use in well-ventilated
area. If adhesive, solvent, or sealing compound gets on skin or clothing, wash immediately
with soap and water. Failure to comply may result in injury or death to personnel.
3.
Apply pipe thread sealing to threads of drain plug (Figure 1, Item 1).
4.
Install water pump drain plug (Figure 1, Item 1) in water pump (Figure 1, Item 2).
5.
Remove drain pan and dispose of used oil IAW local procedures.