Figure 17. Water Tank Installation.
Figure 1. Water Pump Oil Service.

Field Maintenance Manual Tools List For Engineer Mission Module - Water Distributor Page Navigation
  1061    1062    1063    1064    1065  1066  1067    1068    1069    1070    1071  
img
. . . . . . .
TM 5-3825-270-23&P
0196
FIELD MAINTENANCE
WATER PUMP OIL SERVICE
INITIAL SETUP:
References
Tools and Special Tools
Parts Manual (WP 0220) Figure 4011
Tool Kit, General Mechanic's: Automotive
(WP 0225, Table 1, Item 12)
Pan, Drain, 5 Gal Cap (WP 0225, Table 1, Item 2)
Equipment Condition
Funnel, Rigid Spout, 2 QT Cap (WP 0225, Table 1,
Engine OFF. (TM 5-3825-270-10)
Item 2)
Materials/Parts
Compound, Sealing, Pipe Thread, Loctite 567
(WP 0224, Table 1, Item 23, 24, 25, 26)
Oil, SAE-30 (WP 0224, Table 1, Item 49, 50, 51)
DRAIN
WARNING
Prolonged contact with lubricating oil may cause skin rash. Immediately wash skin and
clothing thoroughly and remove saturated clothing that comes in contact with lubricating oil.
Keep area well-ventilated to keep fumes at a minimum. Failure to comply may result in injury
or death to personnel.
NOTE
Dispose of used oil, contaminated rags, and drain pan contents IAW local procedures.
1.
Position drain pan under water pump drain plug (Figure 1, Item 1).