Figure 4. Water Pump Inlet Gauge and Hose Removal.
Figure 7. Water Pump Inlet Gauge and Hose Installation.

Field Maintenance Manual Tools List For Engineer Mission Module - Water Distributor Page Navigation
  980    981    982    983    984  985  986    987    988    989    990  
img
.
TM 5-3825-270-23&P
0178
INSTALLATION - Continued
WARNING
Adhesives, solvents, and sealing compounds can burn easily, can give off harmful vapors,
and are harmful to skin and clothing. Keep away from open fire and use in well-ventilated
area. If adhesive, solvent, or sealing compound gets on skin or clothing, wash immediately
with soap and water. Failure to comply may result in injury or death to personnel.
NOTE
Perform Step (2) if fitting was removed.
2.
Apply sealing compound to threads of fitting (Figure 6, Item 4) and install on gauge (Figure 6, Item 9).
4
9
Figure 6. Water Pump Inlet Gauge and Hose Installation.
3.
Install gauge (Figure 7, Item 9) on control panel (Figure 7, Item 3) with two brackets (Figure 7, Item 7) and
nuts (Figure 7, Item 8).