TM 5-3825-270-23&P
0168
INSTALLATION - Continued
11.
Coat threads of fitting (Figure 8, Item 12) with pipe thread sealant.
12.
Install fitting (Figure 8, Item 12) on right solenoid valve (Figure 8, Item 11).
13.
Install right solenoid valve (Figure 8, Item 11) on frame (Figure 8, Item 10) with two screws (Figure 8, Item 15)
and locknuts (Figure 8, Item 16).
14.
Install hose (Figure 8, Item 6) on fitting (Figure 8, Item 17) with clamp (Figure 8, Item 18).
15.
Install hose (Figure 8, Item 14) on fitting (Figure 8, Item 12) with clamp (Figure 8, Item 13).
16.
Connect right solenoid valve connector lead (Figure 9, Item 9) to harness connector (Figure 9, Item 8).
8
9
Figure 9. Solenoid Valve Installation.
WARNING
Adhesives, solvents, and sealing compounds can burn easily, can give off harmful vapors,
and are harmful to skin and clothing. Keep away from open fire and use in well-ventilated
area. If adhesive, solvent, or sealing compound gets on skin or clothing, wash immediately
with soap and water. Failure to comply may result in injury or death to personnel.
17.
Coat threads of fitting (Figure 10, Item 4) with pipe thread sealant.