Figure 6. Solenoid Valve Installation.
Figure 9. Solenoid Valve Installation.

Field Maintenance Manual Tools List For Engineer Mission Module - Water Distributor Page Navigation
  929    930    931    932    933  934  935    936    937    938    939  
img
.
TM 5-3825-270-23&P
0168
INSTALLATION - Continued
20
19
Figure 7. Solenoid Valve Installation.
WARNING
Adhesives, solvents, and sealing compounds can burn easily, can give off harmful vapors,
and are harmful to skin and clothing. Keep away from open fire and use in well-ventilated
area. If adhesive, solvent, or sealing compound gets on skin or clothing, wash immediately
with soap and water. Failure to comply may result in injury or death to personnel.
9.
Coat threads of fitting (Figure 8, Item 17) with pipe thread sealant.
10
11 12
13 14
15, 16
15, 16
18
6
17
Figure 8. Solenoid Valve Installation.
10.
Install fitting (Figure 8, Item 17) on right solenoid valve (Figure 8, Item 11).