Figure 2. Air Line Lubricator Removal.
Figure 4. Air Line Lubricator Installation.

Field Maintenance Manual Tools List For Engineer Mission Module - Water Distributor Page Navigation
  934    935    936    937    938  939  940    941    942    943    944  
img
.
TM 5-3825-270-23&P
0169
INSTALLATION
WARNING
Adhesives, solvents, and sealing compounds can burn easily, can give off harmful vapors,
and are harmful to skin and clothing. Keep away from open fire and use in well-ventilated
area. If adhesive, solvent, or sealing compound gets on skin or clothing, wash immediately
with soap and water. Failure to comply may result in injury or death to personnel.
NOTE
Install air line lubricator as noted prior to removal.
1.
Apply sealing compound to threads of fitting (Figure 3, Item 4).
2
4
Figure 3. Air Line Lubricator Installation.
2.
Install fitting (Figure 3, Item 4) on air line lubricator (Figure 3, Item 2).
3.
Apply sealing compound to threads of fitting (Figure 4, Item 1).
0169-3