Figure 7. UPIK Electrical Connection - Step 6.
Figure 10. UPIK Harness Connector Pin B - Step 7.

Field Maintenance Manual Tools List For Engineer Mission Module - Water Distributor Page Navigation
  334    335    336    337    338  339  340    341    342    343    344  
img
. . .
TM 5-3825-270-23&P
0060
CONDITION/INDICATION
Are less than 200 ohms measured at UPIK harness connector pin C to known good ground?
DECISION
No - Wiring in water distributor UPIK harness is faulty. Replace UPIK harness. (WP 0108) Verify problem is
solved. (Step 8 - Does cab control box engine speed RESUME/IDLE switch operate?)
Yes - Wiring in cab control box harness is faulty. Replace cab control box wiring harness. (WP 0206) Verify
problem is solved. (Step 8 - Does cab control box engine speed RESUME/IDLE switch operate?)
STEP 7
Are less than 200 ohms measured at UPIK harness connector pin B to known good ground?
1.
Disconnect water distributor UPIK electrical harness from prime mover.
UPIK AIR
CONNECTION
UPIK
ELECTRICAL
CONNECTION
Figure 9. UPIK Electrical Connection - Step 7.
2.
Ensure multimeter is set to measure continuity.
WARNING
Ensure electrical power is off prior to working on all electrical systems. Failure to comply
may result in injury or death to personnel.
Remove all jewelry, such as rings, ID tags, bracelets, etc., prior to working on or around
equipment. Jewelry and tools can catch on equipment, contact positive electrical circuits,
and cause a direct short, severe burns, or electrical shock. Failure to comply may result
in injury or death to personnel.
3.
Connect red multimeter lead to UPIK harness connector pin B.