Figure 9. Master Power Control Switch
Figure 12. Master Power Control Switch.

Technical Manual For Water Well Drilling System (Wwds) - 2 Page Navigation
  292    293    294    295    296  297  298    299    300    301    302  
img
. .
TM 5-3820-276-10-2
0180
ENGINE CRANKS BUT DOES NOT START - PAC - Continued
CORRECTIVE ACTION - Continued
WARNING
DO NOT allow battery acid to contact eyes, skin, or fabric. Upon contact with
eyes or skin, immediately flush with water, apply first aid and obtain medical
attention. DO NOT lean over battery when connecting or disconnecting battery
cables. DO NOT allow negative and positive cables to touch each other. Keep
open flame or sparks away from battery vent holes. ALWAYS wear eye
protection when working with batteries. Failure to comply may result in injury or
death to personnel. Seek medical attention in the event of an injury.
3.
Verify if battery cable terminals are loose, disconnected, damaged, or corroded (WP 0201).
a.
If loose, disconnected, damaged, or corroded, notify maintenance.
b.
If battery cable terminals are not loose, disconnected, damaged or corroded, proceed to
next MALFUNCTION - Battery voltage low.
MALFUNCTION
Battery voltage low.
CORRECTIVE ACTION
1.
Position battery disconnect switch to I (On) position (Figure 11).
BATTERY
DISCONNECT
OFF
ON
SWITCH
POSITION
POSITION
WWDS00199
Figure 11. Battery Disconnect Switch.
0180-7