• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
Figure 2. Battery Disconnect Switch
Figure 4. Battery Disconnect Switch

Technical Manual For Water Well Drilling System (Wwds) - 2 Page Navigation
  296    297    298    299    300  301  302    303    304    305    306  
img
.
TM 5-3820-276-10-2
0181
ENGINE DOES NOT CRANK - PAC - Continued
MALFUNCTION
One or more fuses unserviceable (blown).
CORRECTIVE ACTION
WARNING
Do not wear jewelry when working on electrical circuits. Serious electrical shock
or death by electrocution may result. Failure to comply may result in injury or
death to personnel. Seek medical attention in the event of an injury.
One at a time, remove fuses F1, F2, and F3 and verify if they are unserviceable (blown)
(Figure 3).
FUSE
FUSE
FUSE
F3
F2
F1
WWDS00215
Figure 3.
Fuses F1, F2, and F3.
a.
If fuses F1, F2, or F3 is unserviceable (blown), replace with correct fuse if readily
available. Verify if engine starts (Volume 1, WP 0059). If the correct fuse is not readily
available, notify maintenance.
b.
If fuses F1, F2, and F3 are serviceable (not blown), proceed to next MALFUNCTION -
Battery voltage low.
0181-3
02/13/2013root(tswp)wpno(T30005)