• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
Figure 2. Master Power Control Switch
Figure 6. Battery Disconnect Switch

Technical Manual For Water Well Drilling System (Wwds) - 2 Page Navigation
  288    289    290    291    292  293  294    295    296    297    298  
img
.
TM 5-3820-276-10-2
0180
ENGINE CRANKS BUT DOES NOT START - PAC - Continued
CORRECTIVE ACTION - Continued
LOW FUEL
LEVEL FAULT
INDICATOR
WWDS00274
Figure 4.
LOW FUEL LEVEL Fault Indicator.
5.
Position master power control switch to STOP position. See Figure 2.
6.
Position battery disconnect switch to O (Off) position. See Figure 1.
a.
If fuel level is low, fill to appropriate level with fuel (Volume 1, WP 0056).Verify if engine
starts (Volume 1, WP 0059).
b.
If fuel level is adequate for operation, proceed to next MALFUNCTION - Fuel crossover
valves in closed position.
MALFUNCTION
Fuel crossover valves in closed position.
CORRECTIVE ACTION
Verify fuel crossover valves are in open position (Figure 5).
FUEL
CROSSOVER
VALVES
WWDS00271
Figure 5.
Fuel Crossover Valves.
0180-3
02/13/2013root(tswp)wpno(T30004)