• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
Figure 6. Battery Disconnect Switch
Figure 9. Master Power Control Switch

Technical Manual For Water Well Drilling System (Wwds) - 2 Page Navigation
  290    291    292    293    294  295  296    297    298    299    300  
img
. . . . . .
TM 5-3820-276-10-2
0180
ENGINE CRANKS BUT DOES NOT START - PAC - Continued
CORRECTIVE ACTION - Continued
3.
Check if RESTRICTED AIR FILTER indicator is illuminated (Figure 8).
RESTRICTED
AIR
FILTER
INDICATOR
WWDS00212
Figure 8.
RESTRICTED AIR FILTER Indicator.
4.
Position master power control switch to STOP position. See Figure 7.
a.
If RESTRICTED AIR FILTER indicator illuminates, clean air filter (WP 0214) or remove
restriction. Verify if engine starts (Volume 1, WP 0059).
b.
If RESTRICTED AIR FILTER indicator does not illuminate, proceed to next
MALFUNCTION - Engine coolant level low.
MALFUNCTION
Engine coolant level low.
CORRECTIVE ACTION
NOTE
Engine controller is programmed not to start if engine coolant level is low.
Check engine coolant level (WP 0201).
a.
If engine coolant level is low, fill to appropriate level (WP 0216).
b.
If engine coolant level is correct, proceed to next MALFUNCTION - Engine and/or
compressor fault code present.
MALFUNCTION
Engine and/or compressor fault code present.
CORRECTIVE ACTION
1.
Verify if engine fault codes are present (WP 0177).
2.
Verify if compressor fault codes are present (WP 0178).