TRIPLEX PUMP DOES NOT OPERATE PROPERLY - MCS - Continued
Figure 2. SYSTEM POWERED Indicator.

Technical Manual For Water Well Drilling System (Wwds) - 2 Page Navigation
  253    254    255    256    257  258  259    260    261    262    263  
img
. . .
TM 5-3820-276-10-2
0173
OPERATOR MAINTENANCE
AUXILIARY POWER UNIT (APU) SYSTEM POWERED INDICATOR DOES NOT ILLUMINATE - MUD
CLEANING SYSTEM (MCS)
INITIAL SETUP:
References
Equipment Condition
Volume 1, WP 0054
Engine off (Volume 1, WP 0050)
WP 0174
Catwalks open (Volume 1, WP 0049)
TROUBLESHOOTING PROCEDURE
APU SYSTEM POWERED INDICATOR DOES NOT ILLUMINATE - MCS
SYMPTOM
Green SYSTEM POWERED indicator does not illuminate when attempting to operate APU.
MALFUNCTION
Green SYSTEM POWERED indicator fails push-test.
CORRECTIVE ACTION
1.
Start APU (Volume 1, WP 0054).
2.
Position GENERATOR switch to ON position (Figure 1).
GENERATOR
SWITCH
WWDS00699
Figure 1.
GENERATOR Switch.
0173-1
02/13/2013root(tswp)wpno(T40008)