Figure 10. Mud Cleaning System Hydraulic Valves Post Operation.
Figure 12. Drilling Rig Auxiliary Connections Post Operation.

Technical Manual For Water Well Drilling System (Wwds) - 1 Page Navigation
  668    669    670    671    672  673  674    675    676    677    678  
img
.
TM 5-3820-276-10-1
0067
POST AUXILIARY MUD PUMP OPERATION - Continued
WARNING
Do not open or disconnect hydraulic hoses or fittings while the hydraulic oil is hot or under
pressure. Hydraulic oil is flammable and harmful to the skin and eyes. The hydraulic tanks
and metal parts can be hot. Wear work gloves and eye protection when handling hydraulic
hoses, motors, and hydraulic parts. If hydraulic oil contacts skin, wash the affected area
immediately. In case of eye contact, flush with water for 15 minutes. Dispose of hydraulic
oil in accordance with standard operating procedures. Failure to comply may result in injury
or death to personnel. Seek medical attention in the event of an injury.
4.
Disconnect hose (Figure 11, Item 2) from drilling rig connection (Figure 11, Item 1).
1
2
4
3
WWDS00578
Figure 11. Mud Pump Auxiliary Hose Connections Post Operation.
5.
Disconnect hose (Figure 11, Item 3) from drilling rig connection (Figure 11, Item 4).
6.
Install cap (Figure 12, Item 3) to drilling rig connection (Figure 12, Item 4).