Figure 4. Water Tank Gauge
Figure 6. Off Load Water - Water Pump Connections (Shutoff Valve Shown Closed).

Technical Manual For Water Well Drilling System (Wwds) - 1 Page Navigation
  455    456    457    458    459  460  461    462    463    464    465  
img
.
TM 5-3820-276-10-1
0036
WWSV WATER PUMP OPERATION OFF-LOAD WATER
WARNING
Always wear double hearing protection, safety glasses, hard hat, gloves, and steel toe
shoes during operation of the Water Well Drilling System. Failure to comply may result in
injury or death to personnel. Seek medical attention in the event of an injury.
NOTE
Water pump has two modes of operation: (1) to load water, (REVERSE position), and (2)
to off-load water, (ON position).
1.
Depress clutch pedal (Figure 5, Item 4).
1
2
3
4
WWDS00618
Figure 5.
Engaging P.T.O.
2.
Push button (Figure 5, Item 1) and move P.T.O. lever (Figure 5, Item 2) to IN position.
NOTE
Light illuminates when P.T.O. is engaged.
3.
Check P.T.O. engaged light (Figure 5, Item 3).
4.
Slowly release clutch pedal (Figure 5, Item 4).
0036-6
02/13/2013root(opusualwp)wpno(O20006)