• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
Figure 5. Engaging P.T.O.
Figure 7. Water Pump Disconnect (Shutoff Valve Shown Closed)

Technical Manual For Water Well Drilling System (Wwds) - 1 Page Navigation
  456    457    458    459    460  461  462    463    464    465    466  
img
.
TM 5-3820-276-10-1
0036
WWSV WATER PUMP OPERATION OFF-LOAD WATER - Continued
5.
Connect hose (Figure 6, Item 7) to the water pump fitting (Figure 6, Item 6).
4
5
2
1
3
6
7
7
WWDS00179
Figure 6.
Off Load Water - Water Pump Connections (Shutoff Valve Shown Closed).
6.
Connect opposite end of hose (Figure 6, Item 7) to shutoff valve (Figure 6, Item 2).
7.
Connect second hose (Figure 6, Item 4) to water pump (Figure 6, Item 5).
8.
With aid of an assistant, hold open end of hose (Figure 6, Item 4) at required location.
9.
Rotate handle (Figure 6, Item 1) on shutoff valve (Figure 6, Item 2) to open position.
10.
Push WATER PUMP lever (Figure 6, Item 3) to ON position to off-load water from WWSV.
END OF TASK
0036-7
02/13/2013root(opusualwp)wpno(O20006)