TM 10-4930-236-13&P
DISASSEMBLY
a.
Unscrew spout (1) and remove O-ring packing (2), gasket (3) and strainer element (4) from body (5).
NOTE
Further disassembly should only be performed to the extent
required for parts replacement.
b.
Unscrew and remove coupling half (6). If gasket (7) is damaged, remove gasket from coupling half.
c.
Unscrew contact (9) from body (5) and remove static discharger (8). Hold nut (10) and unscrew plug
(11) from nut. Pull nut (10) from cable (12) only if it requires replacement.
d.
To remove chain (15) and/or spring (16), spread open e-hooks (17) and disconnect chain (15) and
spring (16)
e.
Spread open the other end of e-hooks (17) to remove them from the body (5) and cap (18).
REPAIR
WARNING
Drycleaning solvent, P-D-680A, used to clean parts is potentially
dangerous to personnel and property. Avoid repeated and
prolonged contact. Do not use near open flame or excessive
heat. Flash point of solvent is 100 degrees F -138 degrees F
(38 degrees C-59 degrees C).
a.
Clean all metal parts with drycleaning solvent and dry thoroughly.
4-20