TM 10-4930-236-13&P4-10. DISPENSING NOZLE MAINTENANCEThis task consists of:a.Removalb.Disassembyc.Repaird.Assemblye.InstallationINITIAL SETUPToolsRequiredGeneral Mechanic Tool Kit (Appendix B, Section III, Item 3)Pipe Wrench (Appendix B, Section III, Item 2)Materials/PartsRequiredDrycleaning Solvent (Appendix E, Section II. Item 1)Silicone Compound (Appendix E, Section II, Item 5)Sealing Compound (Appendix E, Section II, Item 6)Rags, Wiping (Appendix E, Section II, Item 13)Suitable ContainerO-Ring Packing (1) (Appendix F)Gasket (1) (Appendix F)EquipmentConditionPumping Unit ShutdownGeneralSafetyInstructionsWARNINGDrycleaning solvent is potentially dangerous to personnel and property.Using compressed air can be dangerous.Silicone compound is toxic to skin, eyes and respiratory tract.REMOVALa.Position a suitable container beneath nozzle (1), remove cap (2) and operate nozzle lever (3) to drainany fuel from nozzle.b.Pull out on cam lock arms (4) of coupling half (5) and disconnect nozzle (1) from reel hose (6).4-19