TM 10-4930-204-13
(1) Clean metal parts with drycleaning solvent (item 1,
App . F), and dry thoroughly.
Clean hose surface with a clean, dry,
cloth .
(2) Inspect
(3) Replace
c.
Installation.
bonding wires.
4-32.
FUEL DISPENSING
nozzles for signs of deterioration and wear.
defective nozzles, as necessary.
Refer to figure 4-6 and install nozzles and
HOSE REEL ASSEMBLY.
a.
General.
The two hose reels have a recoil tension spring to
wind the 40-foot discharge hoses on. the reels.
The product enters
each reel from the filter/separator through a pipe at the hub of the
reel and is discharged through the hoses.
b.
Removal.
NOTE
Remove hoses from reels (para 4-20) and release
recoil spring tension before removing reels.
(1) Pull discharge
wound from reels.
Disconnect
(2) Release spring
(12 turns).
hoses out until they are completely un-
hoses.
tension on reel by turning reel backward
Do not disassemble spring housing as the spring
is under tension and can cause serious injury or
death.
(3) Refer to figure 4-30 (model as applicable) and remove
the hose reels, hose rollers and spring housing.
c.
Cleaning and Inspection.
Drycleaning solvent normally has a flash point
of either 100 or 138 degrees F, depending on the
type being used, but may flash at much lower tem-
peratures if contaminated with gasoline or jet
fuel.
Avoid repeated and prolonged skin contact.
Do not use near open flame or excessive heat.
4-57