TM 10-4930-204-13
(6) Close
(7) Close
draincock.
pressure vent valve.
4-29.
MANIFOLD, LIQUID DISTRIBUTOR AND THREE-WAY VALVE.
The manifold controls the flow of the product to the suction side
of the pump.
Two quick-disconnect couplers provide connections or in-
lets for the tank suction lines.
Flow of the product from either or
both tanks is conducted to the pump suction through the manifold out-
let and a section of hose.
Models 2938 and 36W50 are equipped with a
discharge hose running from the filter/separator to the manifold which
permits discharging from the manifold outlet when the three-way valve
is positioned to close off the suction side.
Models 2519 and Style 1
can use the manifold for suction only and the three-way valve opens or
closes the front and rear inlets on the manifold.
a.
Removal.
(1) Refer to figure 4-28; remove setscrew; disconnect
hoses; remove three-way lever valve.
(2) Remove three nuts, three bolts, and remove manifold.
Figure 4-28.
Manifold and Three-Way Valve, Removal and Installation.
4-54