TM 10-4320-344-242.21.15 Generator Capacitor Replacement, Model 609-C.This task covers:2.21.15.1 Removal2 .21 .1 5 . 2 I n s t a l l a t i onINITIALSETUPToolsGeneral Mechanic’s AutomotiveEquipment Conditions (Continued)Tool Kit, Appendix B, SectionV-Belt Guard removed, paragraph 2.12.15.III, Item 1General Safetv InstructionsMaterials/PartsDo not work on equipment that is notLock Washers (TM 10-4320-303-24P)securely stabilized to prevent rollingo r s l i d i n g.Equipment ConditionsDo not work on equipment with batteryPumping station shut down, TM 10-4320-344-10.connected. Electrocution hazard ispresent if battery is connected.Battery disconnected, paragraph 2.15.3Do not work on equipment without follow-ing standard shop safety practices.2.21.15.1 Removal,a.Open left side engine access door (Figure 2-129, 1) on pumping assembly (2).Do not work on equipment with battery connected.Electrocution hazard ispresent if battery is connected.Failure to obey this warning may result inserious personal injury or death.b .Remove two nuts (3), lock washers (4), and generator capacitor (5) froma l t e r n a t o r ( 6 ).Discard lock washers (4).2.21.15.2 Installation.a.Mount generator capacitor (5) on alternator (6) and secure with two new lockwashers (4) and nuts (3).b .Close left side engine access door (1) on pumping assembly (2).2-296