TM 10-4320-344-242.14.3 Air Cleaner Assembly Maintenance, Model US636HCCD-1. (Continued)Figure 2-34. Air Cleaner Maintenance, Model US636HCCD-1.2.14.3.4 Service.Compressed air used for cleaning purposes must not exceed 30 psi (206.7 kPa).Use only with effective chip guarding and personal protective equipment.Failure to obey this warning may result in personal injury.a.Using compressed air hose clean filter element (12). Blow dust from inside offilter element (12) outward.Clean outside of filter element (12) withcompressed air.b .Cover large end and look through small end of filter element (12).I f l i g htcannot be seen through paper element or hole is present, replace filterelement (12).2-100
Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business