TM 10-4320-344-10Figure 2-18 Pump Discharge Elbow.c .Listen for air escaping from petcock (2).d.Watch for start of water flow from petcock outlet (3).Close petcock (2)when water begins to flow from petcock outlet (3).2.5 OPERATING PROCEDURES.2.5.1 Operation of Model 609-A. The pumping assembly is capable of three modes ofoperation: manual, electric manual, and electric automatic.Use manual or electricmanual mode for startup.Electric automatic mode may be used for sustainedoperation after startup.2.5.1.1 Manual Mode.Before starting Model 609-A, make sure that the pump has beenprimed (paragraph 2.4.1 or 2.4.2).Refer to Figure 2-19 andModel 609-A as follows:start and operatea.Perform "Before" PMCS (Table 2-10).b.Pull out MODE SWITCH (4) to unlock and set to MANUAL THROTTLE position.c .Turn MANUAL THROTTLE (6) clockwise until it is full in.d.Turn FUEL RACK handle (7) counterclockwise to UNLOCK position. Pull handlefully out and turn clockwise to LOCK position.2 - 8 8