TM 10-4320-344-102.5.1.2 Electric Manual Mode. (Continued)Figure 2-20.Model 609-Aand ElectricControl Used for Electric ManualAutomatic Operation.(1) Set ENGINE SWITCH (5) to OFF position.(2) Reset engine alarm by pushing ENGINE ALARM reset button (2).(3) Wait 3 minutes, then repeat step g.h.Turn MANUAL THROTTLE (7) counterclockwise until it is fully out.i .Set PRESSUREIf pump fails toREGULATOR SWITCH (8) to ELECTRIC position.take suction,pump can overheat.Overheated pump cancause severe burns.j .Turn ELECTRIC SPEED CONTROL (6) clockwise until pump takes suet ion, asindicated by pressure reading on PUMP SUCTION gauge (3) or decrease inengine speed as indicated on ENGINE TACHOMETER/HOURMETER (12). If pumpfails to take suction after 3 minutes, shut down engine (step o). Notifyunit maintenance.2-92WARNING