2.5.1.2 Electric Manual Mode. (Continued)
CAUTION
To prevent damage to engine,
DO NOT shut down engine suddenly from
full-load running.
o .
To stop engine, turn ELECTRIC SPEED CONTROL (6) counterclockwise to idle
p o s i t i o n .
Let engine idle for 2 or 3 minutes.
Push ENGINE SWITCH (5) to
OFF position.
Engine will shut down.
p .
Turn FUEL RACK handle (7) counterclockwise and release.
q .
Perform "After" PMCS (Table 2-10).
2.5.1.3 Electric Automatic Mode.
Start and operate Model 609-A as follows:
During startup,
electric manual
CAUTION
all pumping assemblies should be operated in manual or
modes.
a.
b.
c .
Perform steps a through j of paragraph 2.5.1.2.
Turn PRESSURE REGULATOR SWITCH (Figure 2-21,
4) clockwise to AUTO position.
Engine speed is now automatically controlled by the pressure regulator.
The pressure regulator provides 150 psi discharge pressure at suction
pressures of 20 to 120 psi.
Perform "During"
PMCS (Table 2-10).
Figure 2-21.
Model 609-A Controls for Electric Automatic Operation.
2-94
TM 10-4320-344-10