TM10-4320-315-24
2-30. MAINTENANCE OF GOVERNOR ACTUATOR ASSEMBLY
This task covers:
a.
Remove
b.
Install
INITIAL SETUP:
Tools
Equipment Conditions
General Mechanics Tool Kit
Pumping assembly is shutdown (refer to TM 10-4320-
(Item 1, Appendix B)
315-10).
Battery assembly is disconnected (para. 2-16).
Materials/Parts
Tags (Item 21, Appendix C)
Lockwashers (TM 10-4320-315-24P)
a. REMOVE. (Figure 2-17)
(1)
Open engine access door (1).
(2)
Disconnect cable connector (2) from governor actuator assembly (13).
(3)
Remove nut (3) and flat washer (4) from auto defeat cable (5).
(4)
Remove nut (6), bolt (7), and washers (8) and disconnect rod assembly (9).
(5)
Remove governor actuator mounting bolts (10), lockwashers (11), and nuts (12).
(6)
Remove governor actuator (13).
(7)
Remove nut (14), lockwasher (15), bolt (16), and linkage bracket (17). (Retain for installation of actuator.)
b. INSTALL.
(1)
Install linkage bracket (17) with bolt (16), lockwasher (15), and nut (14).
(2)
Install governor actuator (13) with mounting bolts (10), lockwashers (11), and nuts (12).
(3)
Reconnect rod assembly (9) with bolt (7), washers (8), and nut (6).
(4)
Install flat washer (4) and nut (3) on auto defeat cable (5).
(5)
Connect cable connector (2) to governor actuator (13).
(6)
Close engine access door (1).
2-51