TM 10-4320-307-24
2-32
JUNCTION BOX REPAIR/REPLACE.
This task covers:
a. Removal
b. Repair
c. Installation
INITIAL SETUP
Test Equipment
Equipment
Multimeter (Item 12, Appendix B)
Condition
Reference
Condition Description
Tools
Paragraph
Field instrument layout removed
Tool kit, general mechanic's (Item 1, Appendix B)
2-30
Materials/Parts
General Safety Instructions
Crocus abrasive cloth (Item 1, Appendix C)
Well ventilated area
REMOVAL:
NOTE
Four screws (1) are captive.
1.
Loosen four screws (1) and wire (2) securing junction box JB1
cover (3) to junction box (4).
2.
Tag and remove wires from connector X17 (5).
3.
Remove locknut (6) from connector (7).
4.
Remove four screws (8), washers (9), nuts (10) and wire (2)
securing junction box (4) to mounting (11) and remove junction
box.
2-116