TM 10-4320-307-24
2-31
CONDUIT LAYOUT REPAIR/REPLACE (CONT).
REPAIR/INSPECTION:
1.
Repair is limited to replacement of damaged, rusted, or corroded components.
2.
Inspect connectors for cracks, rust, corrosion and for damaged or stripped threads.
INSTALLATION:
1.
Position two brackets (1) on cable bracket (2) and secure using
two bolts, lockwashers, and nuts (3).
2.
Position cable bracket (2) on engine and secure using five
bolts, lockwashers, and spacers (4).
3.
Secure conduit and associated wiring with nylon straps (5).
4.
Position wire and cable in bracket (1).
5.
Secure connector (6) in bracket (1) using locknut (7).
6.
Connect wires (8) to associated sensor (9). Remove tags.
7.
Install field instrument layout in accordance with paragraph 2-
30.
2-115