TM 10-4320-307-24
2-30
FIELD INSTRUMENT LAYOUT TEST/REPAIR/REPLACE (CONT).
20. Remove connector J1 (16) from junction box JB1 (17).
21. Remove nut (18) securing pump delivery pressure transmitter (19) to discharge transducer valve (20).
22. Remove nut (21) securing cable to bracket (22) and remove cable.
23. Separate connector J1 (16), tag and desolder wires from connector, and remove pump delivery pressure transmitter
(19) and associated wiring.
24. Remove connector J2 (23) from junction box JB1 (17).
25. Remove nut (24) securing pump suction pressure transmitter (25) to suction transducer valve (26).
26. Remove nut (27) securing cable to bracket (22) and remove cable.
27. Separate connector J2 (23), tag and desolder wires from connector, and remove pump suction pressure transmitter
(23) and associated wiring.
2-108