TM 5-4320-300-14Table 2-2. Operator/Crew Preventive Maintenance Checks and Services (Continued)B -Before OperationA -After OperationM - MonthlyD -During OperationW -WeeklyINTERVALITEM TO BE INSPECTEDITEMIS NOT READY/NO. B D A W MPROCEDUREAVAILABLE IF6Air Cleaner. Check restriction indicator located in operator'scontrol panel. The red signal in the window of the re-striction indicator locks in view when air cleaner filterelement needs servicing. A button will also pop out ofthe top of the indicator.To clean air filter, loosen clamp assembly that securescup assembly to body assembly. Remove baffle assem-bly and empty dust from the cup assembly.NOTEDo not allow dust to build up in cup assembly.Empty more frequently when operating underdusty conditions.2-12