TM 5-4320-300-14Table 2-2. Operator/Crew Preventive Maintenance Checks and Services - ContinuedB -Before OperationA -After OperationM - MonthlyD -During OperationW -WeeklyINTERVALITEM TO BE INSPECTEDITEMIS NOT READY/NO. B D A W MPROCEDUREAVAILABLE IFWARNINGCompressed air used for cleaning shall not ex-ceed 100 psi (690 kPa). Use goggles or faceshield for eye protection. Do not direct air-stream against skin.If a regulatedcompressed airsupply is avail-able, direct astream of com-pressed air(100 psi (690kPa) maximum)through theelement fromthe inside.CAUTIONDo not blow out body assembly with com-pressed air. Equipment damage could resultif dust is not removed from body assemblywith damp cloth.Reassemble air cleaner by replacing baffle assemblyin cup assembly. Carefully insert filter element inbody assembly and tighten wing nut securely. Re-install cup assembly to body assembly making2-14