TM 5-4320-300-14
Table 4-2. Organizational Maintenance Troubleshooting - Continued
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
If engine is running, shut it down. Leave the PULL TO STOP handle pulled out.
Disconnect tube assembly and fitting at exit from gage.
CAUTION
Do not crank engine more than 30 seconds at
a time. Always allow one-minute intervals
between cranking attempts to allow the
starter motor to cool.
Hold end of tube over a small metal container and crank the engine. Oil should flow from tube within 5 seconds.
If no oil flows from tube within 5 seconds, disconnect tube assembly at entrance to oil gallery.
Remove tube assembly and fittings from engine and remove any obstructions. If tube or fittings
cannot be cleared of blockage, replace tube assembly or fittings as described in paragraph 4-35.
4-62