Section XII. DISCHARGE AND INTAKE PRESSURE LINES
99.1. General
c. Reassembly and Installation. Refer to
The discharge pressure line runs from the
figure 42 to reassemble and install the discharge
discharge side of the pump to the discharge
and intake pressure lines.
pressure gage located on the control panel. The
intake pressure line runs from the intake side of the
Note
pump to the intake pressure gage located on the
Drain the condensate every 24
control panel.
hours under normal operating
condition,
after
every
99.2 Discharge and Intake Pressure Lines
shutdown, and every 4 hours
a. . Removal and Disassembly Refer to
.
in subfreezing temperature.
figure 42 to remove and disassemble the discharge
To drain turn the valves (5
and intake pressure lines.
position then remove plug (34)
b. Cleaning and Inspection.
from gage line. In the event
no readings or incorrect
(1) Clean all parts in an approved
readings on the pressure
cleaning solvent and dry thoroughly.
gages, remove items 8 and 20
and clean thoroughly with
(2) Inspect parts for cracks, bends,
solvent or compressed air.
breaks, or other damage, replace all
missing or damaged parts.
TAGO 6358A
53