TM 5-4320-200-13 & P
4-3.2.
Electric Motor.
This section contains the motor removal procedures.
a.
Removal.
(1) Remove the centrifugal pump as per paragraph 4-4.
(2) Remove the power cable as per paragraph 4-3.1.
(3) Refer to figure 4-6.
Remove nuts (l), washers (2) and
screws (3) that attach motor (4) to frame (5).
Figure 4-6.
Electric Motor Removal.
b . . Cleaning and Inspection.
Drycleaning solvent, P-D-680, used to clean
parts is potentially dangerous to personnel
and property.
Avoid inhalation of fumes
and repeated or prolonged skin exposure.
Wash exposed skin thoroughly with soap and
water.
Use in well ventilated area away
from open flame or excessive heat.
Flash
point is 100 F (38°C).
4-10