ROLLER REPAIR - Continued
ROLLER REPAIR - Continued

Field Maintenance Manual Tools List For Engineer Mission Module - Water Distributor Page Navigation
  860    861    862    863    864  865  866    867    868    869    870  
img
.
TM 5-3825-270-23&P
0153
CLEANING/INSPECTION - Continued
WARNING
Compressed air used for cleaning and drying purposes must not exceed 30 psi (207 kPa).
Use only with effective chip guarding and proper protective equipment (goggles, shield,
gloves, etc.). Failure to comply may result in injury or death to personnel.
2.
Dry components with compressed air.
3.
Inspect lockwires and retaining rings for damage. If necessary, replace lockwires.
4.
Inspect roller for damage that would interfere with rotation.
END OF TASK
ASSEMBLY
NOTE
Perform Step (1) if retaining pins were removed.
1.
Install retaining pins (Figure 2, Item 4) on holding pins (Figure 2, Item 3).
2
3
1
4
5
7
6
Figure 2. Roller Assembly.
2.
Install roller (Figure 2, Item 6) in bracket (Figure 2, Item 2) and secure with roller shaft (Figure 2, Item 5).
3.
Install collar (Figure 2, Item 7) on roller shaft (Figure 2, Item 5).
4.
Secure collar (Figure 2, Item 7) on roller shaft (Figure 2, Item 5) with cotter pin (Figure 2, Item 1).
END OF TASK
0153-3