GLOW PLUG RELAY REPLACEMENT
Figure 3. Glow Plug Relay Removal.

Field Maintenance Manual Tools List For Engineer Mission Module - Water Distributor Page Navigation
  756    757    758    759    760  761  762    763    764    765    766  
img
.
TM 5-3825-270-23&P
0131
REMOVAL - Continued
2.
Remove nut (Figure 1, Item 10), lockwasher (Figure 1, Item 11), and yellow wire (Figure 1, Item 9) from stud
(Figure 1, Item 12). Discard lockwasher.
3.
Remove nut (Figure 1, Item 2), lockwasher (Figure 1, Item 3), and red wire (Figure 1, Item 1) from stud (Figure
1, Item 4). Discard lockwasher.
4.
Remove nut (Figure 2, Item 18), lockwasher (Figure 2, Item 19), and blue wire (Figure 2, Item 17) from stud
(Figure 2, Item 20). Discard lockwasher.
13, 14, 15
16
17
18, 19, 20
Figure 2. Glow Plug Relay Removal.
5.
Remove two nuts (Figure 2, Item 13), lockwashers (Figure 2, Item 14), and glow plug relay (Figure 2, Item 16)
from isolators (Figure 2, Item 15). Discard lockwashers.
NOTE
Perform Step (6) if isolators are damaged.
All isolators are removed the same way. Top isolator shown.
6.
Remove screw (Figure 3, Item 21), lockwasher (Figure 3, Item 22), and isolator (Figure 3, Item 15) from
mounting surface (Figure 3, Item 23). Discard lockwasher.
0131-2