Figure 9. Main Control Box Removal.
Figure 12. Main Control Box Installation.

Field Maintenance Manual Tools List For Engineer Mission Module - Water Distributor Page Navigation
  583    584    585    586    587  588  589    590    591    592    593  
img
.
TM 5-3825-270-23&P
0100
REMOVAL - Continued
54.
Repeat Step (53) for removal of negative terminal strip (Figure 10, Item 2) and interconnect terminal strip
(Figure 10, Item 3).
END OF TASK
INSTALLATION
NOTE
Install terminal strips as noted prior to removal.
Faceplate harness may remain on terminal strips when installing terminal strips from main
control box.
All terminal strips are installed from main control box the same way.
1.
Install positive terminal strip (Figure 11, Item 26) on main control box (Figure 11, Item 4) using two screws
(Figure 10, Item 27), washers (Figure 10, Item 28), lockwashers (Figure 11, Item 29), and nuts (Figure 10, Item
26).
2
3
4
1
10
10
10
26, 27, 28, 29
5
15
15
1
20
20
Figure 11. Main Control Box Installation.
2.
Repeat Step (1) for installation of negative terminal strip (Figure 11, Item 2) and interconnect terminal strip
(Figure 11, Item 3).
3.
Install main control box (Figure 12, Item 4) on frame (Figure 12, Item 22) using three screws (Figure 12, Item
25), six washers (Figure 12, Item 24) and three locknuts (Figure 12, Item 23).