TM 5-3825-270-23&P
0012
DECISION
No - Ensure wire is correctly seated in terminal post. If wiring is correctly seated in terminal, repair or replace
black wire from terminal strip, terminal 4 to governor controller harness connector pin E1. (WP 0099) Verify
problem is solved. (Step 7 - Does engine increase RPM normally?)
Yes - Problem not found and may have been missed or overlooked. Repeat all previous steps in this
troubleshooting procedure. Go to test 1. (Step 1 - Is problem with engine speed present when using main control
panel?) If problem still exists after all troubleshooting test have been accomplished, replace governor
STEP 7
Does engine increase RPM normally?
Start engine and attempt to increase engine RPM while observing engine performance. (TM 5-3825-270-10)
CONDITION/INDICATION
Does engine increase RPM normally?
DECISION
No - If the problem still exists, it is possible that another fault exists or that another troubleshooting procedure
applies. If this was the first time through the task, restart the same symptom troubleshooting fault task.
Yes - Your original problem has been resolved.
END OF WORK PACKAGE