TM 5-3825-270-23&P
0012
Are less than 200 ohms measured on black wire from interconnect terminal strip, terminal 4 to governor
controller harness connector, pin E1?
1.
Connect red multimeter probe to terminal 4 at interconnect terminal strip.
INSIDE OF
15-AMP
CONTROL PANEL
CIRCUIT BREAKER
20
1
1
15
5
5
EMERGENCY
10
10
10
STOP SWITCH
5
15
15
1
20
20
INTERCONNECT
POSITIVE
NEGATIVE
TERMINAL STRIP
TERMINAL STRIP
TERMINAL STRIP
Figure 9. Interconnect Terminal Strip - Step 6.
2.
Connect black multimeter probe to governor controller harness connector pin E1.
GOVERNOR
CONTROLLER
GOVERNOR
CONTROLLER
HARNESS
CONNECTOR
A
E
F
K
3
3
2
2
1
1
Figure 10. Governor Controller Harness Connector Pin E1 - Step 6.
3.
Note multimeter reading.
4.
Connect governor controller harness to governor controller. (WP 0092)
CONDITION/INDICATION
Are less than 200 ohms measured on black wire from interconnect terminal strip, terminal 4 to governor controller
harness connector, pin E1?