CAB CONTROL BOX TACHOMETER DOES NOT OPERATE
ure 4. Cab Control Box Tachometer - Step 3.

Technical Manual For Engineer Mission Module - Water Distributor Page Navigation
  231    232    233    234    235  236  237    238    239    240    241  
img
. . . . .
TM 5-3825-270-10
0066
STEP 2
Are cab control box and water distributor harnesses connected properly to prime mover?
1.
Push EMERGENCY STOP switch in to off position. (WP 0017)
2.
Check cab control box electrical connector.
ELECTRICAL
CAB CONTROL
CONNECTOR
BOX
Figure 2. Cab Control Box - Step 2.
3.
Check prime mover UPIK air and electrical connections.
UPIK AIR
CONNECTION
UPIK
ELECTRICAL
CONNECTION
Figure 3. UPIK Air And Electrical Connections - Step 2.
CONDITION/INDICATION
Are cab control box and water distributor harnesses connected properly to prime mover?
DECISION
No - Properly connect cab control box and/or harness connections to prime mover. (WP 0012) Verify problem
is solved. (Step 3 - Does cab control box tachometer operate?)
Yes - Notify maintenance personnel cab control box tachometer does not operate.
STEP 3
Does cab control box tachometer operate?
1.
Ensure water distributor is set up to be operated using cab control box. (WP 0012)
2.
Start engine. (WP 0017)
3.
Observe cab control box tachometer.