Figure 2. Water Level High indicator - Step 1.
Figure 6. Cab Control Box Water Level High Indicator - Step 3.

Technical Manual For Engineer Mission Module - Water Distributor Page Navigation
  235    236    237    238    239  240  241    242    243    244    245  
img
. .
TM 5-3825-270-10
0067
UPIK AIR
CONNECTION
UPIK
ELECTRICAL
CONNECTION
Figure 4. UPIK Air And Electrical Connections - Step 2.
CONDITION/INDICATION
Are cab control box and water distributor harnesses connected properly to prime mover?
DECISION
No - Properly connect cab control box and/or harness connections to prime mover. (WP 0012) Verify problem
is solved. (Step 3 - Does cab control box WATER LEVEL HIGH indicator illuminate?)
Yes - Notify maintenance personnel cab control box WATER LEVEL HIGH INDICATOR does not illuminate.
STEP 3
Does cab control box WATER LEVEL HIGH indicator illuminate?
1.
Rotate EMERGENCY STOP switch to on position.
EMERGENCY STOP SWITCH
Figure 5. Emergency Stop Switch - Step 3.
2.
Observe cab control box WATER LEVEL HIGH indicator.