TM 5-3825-270-10
0044
ENGINE OFF / BATTERY
DRAIN INDICATOR
Figure 2. Engine Off/Battery Drain Indicator - Step 1.
CONDITION/INDICATION
Does ENGINE OFF/BATTERY DRAIN indicator illuminate at main control panel on rear of water distributor?
DECISION
No - Go to step 2. (Step 2 - Is 15-amp circuit breaker tripped?)
Yes - Ensure water distributor cab control box and harness are properly connected to prime mover universal
power interface kit (UPIK). (WP 0012) Verify problem is solved. (Step 3 - Does water distributor operate
remotely?)
STEP 2
Is 15-amp circuit breaker tripped?
NOTE
The 15-amp circuit breaker works in conjunction with the emergency stop switch to control
power to the control panel. If a power surge is detected, the 15-amp circuit breaker will trip
prohibiting the emergency stop switch to supply power to the control panel and engine.
Verify 15-amp circuit breaker position.
15-AMP
CIRCUIT
BREAKER
CONDITION/INDICATION
Is 15-amp circuit breaker tripped?