Figure 1. Valve V5 - Step 1.
WORK LIGHTS DO NOT OPERATE - Continued

Technical Manual For Engineer Mission Module - Water Distributor Page Navigation
  175    176    177    178    179  180  181    182    183    184    185  
img
. . . . . .
TM 5-3825-270-10
0043
FIELD MAINTENANCE
WORK LIGHTS DO NOT OPERATE
INITIAL SETUP:
References
Equipment Condition
Operating Lights (WP 0006)
Engine OFF. (WP 0017)
Discharge From Hose Reel Assembly (WP 0017)
TROUBLESHOOTING PROCEDURE
WORK LIGHTS DO NOT OPERATE
STEP 1
Are one or both work lights not working?
Operate work lights to determine if one or both are not working. (WP 0006)
CONDITION/INDICATION
Are one or both work lights not working?
DECISION
Both work lights out - Go to step 2. (Step 2 - Is EMERGENCY STOP switch is in the on position?)
One work light out - Notify maintenance personnel left or right work light is inoperative.
STEP 2
Is EMERGENCY STOP switch is in the on position?
NOTE
Water distributor work lights will not illuminate if EMERGENCY STOP switch is in the off
position.
Verify if EMERGENCY STOP switch is rotated out to on position.
EMERGENCY STOP SWITCH
Figure 1. Emergency Stop Switch - Step 2.
CONDITION/INDICATION
Is EMERGENCY STOP switch is in the on position?
0043-1