TM 5-3825-270-10
OPERATOR MAINTENANCE
OPERATING LIGHTS
INITIAL SETUP:
Not Applicable
OPERATING LIGHTS
NOTE
Emergency stop switch must be ON to supply power to the electrical system.
The light switch has three positions: ON is the up position, middle is the OFF position,
and down is the CAB CONTROL position.
1.
Disconnect t-handle (Figure 1, Item 1) from control panel cover (Figure 1, Item 2).
1
2
Figure 1. Operating Lights.
2.
Open control panel cover (Figure 1, Item 2).
3.
Place light switch (Figure 2, Item 3) to ON position to turn work lights (Figure 2, Item 4) on and back to OFF
to turn work lights off.