NO POWER TO MAIN CONTROL PANEL
Figure 4. Emergency Stop Switch - Step 4.

Technical Manual For Engineer Mission Module - Water Distributor Page Navigation
  181    182    183    184    185  186  187    188    189    190    191  
img
. .
TM 5-3825-270-10
0045
15-AMP
CIRCUIT
BREAKER
Figure 2. 15-Amp Circuit Breaker - Step 2.
CONDITION/INDICATION
Is 15-amp circuit breaker tripped?
DECISION
No - Go to step 3. (Step 3 - Are batteries properly connected?)
Yes - Reset 15-amp circuit breaker. Verify problem is solved. (Step 4 - Does water distributor have power?) If
15 amp circuit breaker trips again after reset, do not attempt to reset. Notify maintenance personnel 15-amp
circuit breaker is tripped.
STEP 3
Are batteries properly connected?
1.
Remove battery cover. (WP 0081)
2.
Visually inspect batteries and battery cables to ensure proper connection.
BATTERY
CABLES
BATTERIES
Figure 3. Batteries And Battery Cables - Step 3.
CONDITION/INDICATION
Are batteries properly connected?