Figure 3. Load Tank At Strainer With External Pump.
Figure 6. Load Tank At Strainer With Hydrant.

Technical Manual For Engineer Mission Module - Water Distributor Page Navigation
  115    116    117    118    119  120  121    122    123    124    125  
img
.
TM 5-3825-270-10
0021
LOAD TANK AT STRAINER WITH HYDRANT - Continued
1
4
3
2
Figure 4. Load Tank At Strainer With Hydrant.
4.
Remove cap (Figure 4, Item 2) from suction hose (Figure 4, Item 4).
5.
Connect suction hose (Figure 4, Item 4) to connection point C1 (Figure 4, Item 1).
6.
Remove cap (Figure 5, Item 5) from suction hose (Figure 5, Item 6).
6
4
5
7
Figure 5. Load Tank At Strainer With Hydrant.
7.
Remove cap (Figure 5, Item 7) from suction hose (Figure 5, Item 4).
0021-5