Figure 20. Load Tank At Strainer With System Pump And Floating Strainer.
Figure 1. Load Tank At Strainer With External Pump.

Technical Manual For Engineer Mission Module - Water Distributor Page Navigation
  111    112    113    114    115  116  117    118    119    120    121  
img
. .
TM 5-3825-270-10
0021
OPERATOR MAINTENANCE
LOAD TANK AT STRAINER WITH EXTERNAL PUMP
INITIAL SETUP:
Not Applicable
LOAD TANK AT STRAINER WITH EXTERNAL PUMP
CAUTION
Do not exceed 50 psi inlet pressure while filling tank at connection point C1. Failure to
comply may result in damage to equipment.
Do not exceed 600 GPM fill rate from external pressure source. Failure to comply may
result in damage to equipment.
NOTE
Ensure that all valves and petcocks are in the closed position prior to performing this task.
1.
Unstow hoses (WP 0078).
2.
Remove cap (Figure 1, Item 3) from connection point C1 (Figure 1, Item 1).
0021-1